From capture to output, you work directly with your RAW files, never having to first convert them into another format before viewing, adjusting, organizing, or printing them.And with the most powerful image processing in the world, Aperture is fast — whether you’re working with RAW, JPEG, or TIFF images. It supports the RAW formats from all leading digital camera manufacturers (including Canon and Nikon) and provides optimized support for such market leading cameras as the Canon EOS 1Ds Mark II, Canon EOS 20D, and Nikon D2x as well as the highly popular Canon Digital Rebel and Nikon D50.
![](/uploads/1/2/5/8/125846172/709893773.jpg)
All your photos on all your devices. ICloud Photos gives you access to your entire Mac photo and video library from all your devices. If you shoot a snapshot, slo-mo, or selfie on your iPhone, it’s automatically added to iCloud Photos — so it appears on your Mac, iOS and iPadOS devices, Apple TV, iCloud.com, and your PC.
Measure your beam as never before with the NanoScan™ beam profiler. The advantage of scanning slit beam profiling is sub-micron precision for measuring beam position and size. Scan head configurations include Silicon, Germanium, and Pyroelectric versions for a wide range of wavelengths and laser power levels.
The NanoScan software is available in two versions: Standard and Professional, and includes an extensive set of ISO quantitative measurements, an M2 Wizard, and the ability to measure laser power. This NanoScan scanning-slit profiling system accurately captures and analyzes wavelengths from 190nm - 1100nm with its Silicon detector. It features a slit size suitable for small beams, near real-time data capture rates, an optional power measurement feature, and operates in CW or kHz Pulsed modes which makes it ideal for comprehensive analysis of UV, Visible, and NIR lasers.Beam Sizes of 7µm to 2.3mmPower Levels of 10nW to 10WUSB 2.0 InterfaceNanoScan Standard or Professional software included. This NanoScan scanning-slit profiling system accurately captures and analyzes wavelengths from 190nm - 1100nm with its Silicon detector. It features a slit size suitable for most beams, near real-time data capture rates, an optional power measurement feature, and operates in CW or kHz Pulsed modes which makes it ideal for comprehensive analysis of UV, Visible, and NIR lasers.Beam Sizes of 20µm to 6mmPower Levels of 10nW to 10WUSB 2.0 InterfaceNanoScan Standard or Professional software included.
This NanoScan scanning-slit profiling system accurately captures and analyzes wavelengths from 700nm - 1800nm with its Germanium detector. It features an aperture size suitable for small beams, near real-time data capture rates, an optional power measurement feature, and operates in CW or kHz Pulsed modes which makes it ideal for comprehensive analysis of IR and NIR lasers.Beam Sizes of 7µm to 2.3mmPower Levels of 10nW to 10WUSB 2.0 InterfaceNanoScan Standard or Professional software included. This NanoScan scanning-slit profiling system accurately captures and analyzes wavelengths from 700nm - 1800nm with its Germanium detector. It features an aperture size suitable for most beams, near real-time data capture rates, an optional power measurement feature, and operates in CW or kHz Pulsed modes which makes it ideal for comprehensive analysis of IR and NIR lasers.Beam Sizes of 20µm to 6mmPower Levels of 10nW to 10WUSB 2.0 InterfaceNanoScan Standard or Professional software included. This NanoScan scanning-slit profiling system accurately captures and analyzes wavelengths from 190nm - 100µm with its Pyroelectric detector. It features slit and aperture sizes suitable for most beams, near real-time data capture rates, an optional power measurement feature, and operates in CW or kHz Pulsed modes which makes it ideal for comprehensive analysis of lasers of any wavelength.Beam Sizes of 20µm to 6mmPower Levels of 5mW to 100WUSB 2.0 InterfaceNanoScan Standard or Professional software included. This NanoScan scanning-slit profiling system accurately captures and analyzes wavelengths from 900nm -5μm with its Pyroelectric detector.
It features slit and aperture sizes suitable for most beams, near real-time data capture rates, an optional power measurement feature, and operates in CW or kHz Pulsed modes which makes it ideal for comprehensive analysis of lasers of any wavelength.Beam Sizes of 20µm to 6mmPower Levels of 5mW to 100WUSB 2.0 InterfaceNanoScan Standard or Professional software included. Scanning Slit Beam Profiler For High Accuracy Dimensional MeasurementNanoScan 2s combines the convenience and portability of direct USB connectivity with the speed, accuracy, and dynamic range that users have come to expect from the Photon NanoScan slit based profilers. The NanoScan 2s is available with a silicon, germanium or pyroelectric detector, which allows it to profile lasers of any wavelength from UV to far infrared, out to 100μm and beyond. With the new NanoScan 2s software package, the user can configure the display interface however it is desired; displaying those results of most interest on one easy-to-read screen, or on multiple screens.The NanoScan slit profiler is the most versatile laser beam profiling instrument available today: providing instantaneous feedback of beam parameters for CW and kilohertz pulsed lasers, with measurement update rates to 20Hz. The natural attenuation provided by the slit allows the measurement of many beams with little or no additional attenuation. The high dynamic range makes it possible to measure beams while adjustments to focus are made without having to adjust the profiler.
Just aim the laser into the aperture and the system does the rest!CapabilitiesNanoScan 2s is a PC-based instrument for the measurement and analysis of laser beam spatial irradiance profiles in accordance with the ISO standard 11146. The scan heads also measure power in accordance with ISO 13694.
NanoScan uses the scanning slit, one of the ISO Standard scanning aperture techniques. It can measure beam sizes from microns to centimeters at beam powers from microwatts to over kilowatts, often without attenuation. Detector options allow measurement at wavelengths from the ultraviolet to the infrared.The NanoScan 2s digital controller has 16-bit digitization of the signal for enhanced dynamic range up to 35dB power optical.
![Aperture download for mac Aperture download for mac](/uploads/1/2/5/8/125846172/688913405.jpg)
With the accuracy and stability of the beam profile measurement you can measure beam size and beam pointing with a 3-sigma precision of several hundred nanometers. The software controllable scan speed and a 'peak-connect' algorithm allows the measurement of pulsed and pulse width modulated lasers with frequencies of 10kHz and higher.
![](/uploads/1/2/5/8/125846172/709893773.jpg)